SHIPPING QUOTE FOR OVERSIZED ITEMS MUST BE REQUESTED | WhatsApp Global CLICK HERE

YSI

YSI ProDSS Multiparameter Water Quality Meter

Ref: YSI-626870-1
  • Last Price Update: Aug 2024 (?)
  • If the item is in US stock, the estimated *Processing Time before shipping is: 5-8 6-10 business days. ¿Require Priority Shipping? Let us know to check if it is possible.
    *Processing Time = Preparation, Production, or Importation

  • Coleções: Probes & Parameter Meters, YSI

    Vendedor: YSI


    Shipping Weight: 6.0 kg


    YSI ProDSS Multiparameter Water Quality Meter

    The YSI ProDSS is a highly versatile portable multiparameter device for water quality measurement. It offers two main cable options: a 4-port set compatible with up to four interchangeable sensors or the ODO/CT probe, which combines an optical dissolved oxygen sensor with a conductivity sensor for real-time salinity compensation. Designed for field use, the ProDSS is ideal for applications in surface, groundwater, and wastewater with a rugged, waterproof (IP-67) housing.

    The ProDSS also includes a free online learning platform, ProDSS On-Demand Training, to train users before field operations.

    Note: The instrument is sold separately. Cables, sensors, and accessories are not included.

    Details:

    • Measured Parameters: Dissolved oxygen, turbidity, pH, ORP, conductivity, temperature, salinity, among others.
    • Cable Options: 4-port cable or ODO/CT probe.
    • Durability: Waterproof housing (IP-67) and military-spec connectors.
    • Free Training: ProDSS On-Demand Training.
    • Benchtop Yes, optical BOD probe for the lab is available
      Buffer Recognition Auto-buffer recognition for USA (4.00, 7.00, 10.00) and NIST (4.01, 6.86, 9.18) buffer sets. Calibration values automatically compensated for temperature.
      Certifications FCC, WEEE, UN Part III Section 38.3 test methods for lithium-ion batteries (class 9), RoHS, Assembled in USA, IP-67, 1-meter drop test, CE
      Connectivity / Communications Built-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick
      Connector MS (military spec) waterproof with quarter-turn bayonet lock
      Data Management KorDSS desktop PC software (included), >100,000 data sets
      Desktop Software Compatible KorDSS desktop PC software (included)
      Digital / Digital Sensors Yes
      Flow Cell Yes, flow cell is available
      GLP Compliance Yes, detailed GLP information is stored and available to view, download or print
      GPS Optional internal GPS, coordinates stored with measurement data and site lists
      Graphic Display Color, LCD graphic display, backlit keypad
      Languages Italian, German, Norwegian, English, French, Portuguese, Japanese, Chinese (Simplified & Traditional), Spanish
      Logging Capabilities Single point or Continuous
      Measurement Method / Channels Digital
      Memory >100,000 data sets, 400 GLP files
      Multiparameter Yes
      Operating Temperature 0 to 50°C (32 to 122°F)
      Parameters Measured Dissolved Oxygen (%), Dissolved Oxygen (mg/L), Temperature, Turbidity, Conductivity, Specific Conductance, Resistivity, Salinity, Water Density, pH, ORP, Ammonium, Nitrate, Chloride, TDS, TSS, Depth, Barometer
      Power Rechargeable lithium-ion battery pack providing ~48 hours of battery life
      Sampling Yes
      Security / Password Protection / UserID Yes
      Size Instrument: 8.3 cm width x 21.6 cm length x 5.6 cm depth (3.27 in x 8.5 in x 2.21 in)
      Bulkhead with sensors, without depth: 33.3 cm (13.11 in) length
      Bulkhead with guard, without depth: 42.82 cm (16.86 in) length and 4.75 cm (1.87 in) outer diameter
      Smart Sensors / Ports 4 universal sensor ports on each cable, can accept any ProDSS sensor
      Storage Temperature 0 to 45°C (32 to 113°F) with battery, 0 to 60°C (32 to 140°F) without battery
      User Calibratable Yes
      User Replaceable Yes
      Warranty 3-year instrument; 2-year bulkhead, cable assembly, and sensors; 1-year pH and pH/ORP sensor modules, ODO sensor caps, and Li-Ion battery pack; 6-month ammonium, nitrate, and chloride sensor modules
      Waterproof Floats, IP-67 (even with the battery cover off)


      ProDSS System Specifications (Instrument, Cables & Sensors)

      Parameter Method Range Accuracy Resolution Calibration Points Maximum Depth
      Dissolved Oxygen (% saturation) Optical Luminescence - Lifetime Method 0 to 500% 0 to 200% (±1% of reading or 1% air saturation, whichever is greater)
      200% to 500% (±8% of reading)
      0.1% or 1% air saturation (user selectable) 1 or 2 points 100 m
      Dissolved Oxygen (mg/L, ppm) Optical Luminescence - Lifetime Method 0 to 50 mg/L 0 to 20 mg/L (±0.1 mg/L or 1% of reading, whichever is greater)
      20 – 50 mg/L (±8% of reading)
      0.1 or 0.01 mg/L (user selectable) 1 or 2 points (user selectable) 100 m
      Temperature (°C, °F, K) Thermistor; Combination Sensor with Conductivity -5 to 70°C (23 to 158°F) ±0.2°C 0.1°C or 0.1°F (user selectable) None 100 m
      Turbidity (FNU, NTU) Nephelometric - Optical, 90° Scatter 0 to 4000 FNU 0 to 999 (0.3 or ±2% of reading, whichever is greater)
      1000 to 4000 (±5% of reading)
      0.1 FNU 1, 2, or 3 points (user selectable) -
      Conductivity* (µS, mS) Four Nickel Electrode Cell 0-100 mS/cm 0 to 100 mS/cm (±0.5% of reading or 0.001 mS/cm, whichever is greater)
      100 to 200 mS/cm (±1% of reading)
      0.001, 0.01 or 0.1 mS/cm (range dependent) 1 point 100 m
      Specific Conductance (µS, mS) Calculated from Conductivity and Temperature 0 to 200 mS/cm ±0.5% of reading or 0.001 mS/cm, whichever is greater 0.001, 0.01, 0.1 mS/cm 1 point -
      Resistivity (ohm-cm, kohm-cm, Mohm-cm) Calculated from Conductivity and Temperature 0 to 2 Mohms ±0.1% Full Scale 0.001, 0.01, 0.1 ohms - -
      Salinity (ppt, PSU) Calculated from Conductivity and Temperature 0 to 70 ppt ±1.0% of reading or ±0.1 ppt, whichever is greater 0.01 ppt 1 point -
      Water Density (Sigma, Sigma T) Sigma is Calculated from Salinity, Temperature, and Pressure
      Sigma T is Calculated from Salinity and Temperature
      0.0 to 50.0 sigma, sigma T - 0.1 sigma or sigma T - -
      pH (mV, pH units) Glass Bulb Combination Electrode; Ag/AgCl Reference Gel 0 to 14 units ±0.2 units 0.01 units 1, 2, or 3 points (user selectable) 100 m
      ORP (mV) Platinum Button; Ag/AgCl Reference --1999 to +1999 mV ±20 mV 0.1 mV 1 point 100 m
      Ammonium** (NH4-N mg/L, NH4-N mV) ammonia with pH sensor
      Ion Selective Electrode
      0 to 200 mg/L NH4-N ±10% of reading or 2 mg/L, whichever is greater 0.01 mg/L 1, 2, or 3 point (user selectable) 20 m
      Ammonia*** (NH3-N mg/L) Calculated from Ammonium, Temperature, Salinity and pH 0 to 200 mg/L NH4-N - 0.01 mg/L - -
      Nitrate** (NO3-N mg/L, NO3-N mV) Ion Selective Electrode 0 to 200 mg/L NO3-N ±10% of reading or 2 mg/L, whichever is greater 0.01 mg/L 1, 2, or 3 point (user selectable) 20 m
      Chloride** Ion Selective Electrode 0 to 1000 mg/L Cl ±15% of reading or 5 mg/L, whichever is greater 0.01 mg/L 1, 2, or 3 point (user selectable) 20 m
      Total Dissolved Solids (TDS) (mg/L, kg/L, g/L) Calculated from Conductivity and Temperature 0 to 100 g/L User-Selectable TDS Multiplier (0.30 to 1.00; 0.65 default) 0.001, 0.01, 0.1g/L - -
      Total Suspended Solids (TSS) (mg/L) Correlated from Turbidity Field Measurements and Lab TSS Measurements from Grab Samples 0 to 30000 mg/L Calculated from Turbidity and User-Entered Correlation Points 0.01, 0.1 mg/L - -
      Chlorophyll (RFU or µg/L chl) Optical Luminescence 0 to 100 RFU or 0 to 400 µg/L chl Linearity: r2 ≥ 0.999 for Rhodamine WT across full range 0.01 RFU or 0.01 µg/L chl 2 point -
      Phycocyanin (RFU or µg/L PC) Optical Luminescence 0 to 100 RFU or 0 to 100 µg/L PC Linearity: r2 ≥ 0.999 for Rhodamine WT across full range 0.01 RFU or 0.01 µg/L PC 2 point -
      Phycoerythrin (RFU or µg/L PE) Optical Luminescence 0 to 100 RFU or 0 to 280 µg/L PE Linearity: r2 ≥ 0.999 for Rhodamine WT across full range 0.01 RFU or 0.01 µg/L PE 2 point -
      Depth (m, ft) Pressure Transducer 0 to 100 m (0 to 328 ft) ±0.004 m (±0.013 ft) for 1, 4 and 10-m cables
      ±0.04 m (±0.13 ft) for cables 20-m and longer
      0.001 m or 0.01 ft 1 point -
      Barometer (mmHg, inHg, mbar, psi, kPa, ATM) Piezoresistive 375 to 825 mmHg ±1.5 mmHg from 0 to 50°C 0.1 mmHg 1 point -
      • YSI ProDSS Handheld Meter.
    • Depending on your needs, the following sensors may be required:

      • Dissolved Oxygen (DO) sensor
      • Turbidity sensor
      • pH/ORP sensor
      • Conductivity sensor
      • Temperature sensor
      • None