SHIPPING QUOTE FOR OVERSIZED ITEMS MUST BE REQUESTED | WhatsApp Global CLICK HERE
Request Quote
The Edge® pH/ORP dedicated meter combines the advanced functionality of a laboratory instrument with the portability of a tablet-style design. Thanks to its intelligent diagnostic system and compatibility with digital electrodes, it ensures accurate and reliable results at all times. Designed for scientists, technicians, and demanding professionals, this meter enables reliable measurements in the field or laboratory with an intuitive interface and multiple connectivity options.
Parameter | Value |
---|---|
pH Range | -2.000 to 16.000 (Standard Mode), -2.00 to 16.00 (Basic Mode) |
pH Resolution | 0.001 / 0.01 pH |
pH Accuracy | ±0.002 / ±0.01 pH |
pH Calibration | Up to 5 points (standard mode), 3 points (basic mode) |
Temperature Compensation | ATC: -5.0 to 100.0 °C (23.0 to 212.0 °F) |
mV Range | ±1000.0 mV; ±2000.0 mV |
mV Resolution / Accuracy | 0.1 mV / ±1000.0 mV; ±2000.0 mV |
mV Calibration | 1 point |
Temperature Range | -20.0 to 120.0 ºC / -4.0 to 248.0 ºF |
Temperature Resolution / Accuracy | 0.1 °C / ±0.5 °C |
Electrode Diagnostics | Glass and reference junction (HI11311 & HI12301) |
GLP | Yes |
Logging Capacity | Up to 1000 readings (manual, by stability, or at intervals) |
Connectivity | 1 micro-USB port, 1 standard USB port |
Environmental Conditions | 0 to 50 °C, max RH 95% non-condensing |
Battery | Rechargeable, up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Ver todos os detalhes do produto »
$ 3,777.90 USD
The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.
*Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.
The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default, the HI9829 and the corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.
HI7609829 Basic Probe |
HI7629829 Autonomously Logging Probe |
---|---|
|
|
The HI7609829 (logging) is a multiparameter pH/ISE/EC/DO/Turbidity/Temperature probe for use with the HI9829 portable meter. Sensors are automatically recognized by the probe and meter when connected. Sensor replacement is quick and easy with field replaceable, screw type connectors that are color-coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, and 20m lengths available. It’s rugged, waterproof design makes it ideal for field use. The probe is suitable for installation in confined locations such as air vaults, river intakes, vertical wells, tanks, etc.. The streamline diameter of the probe permits insertion into 2" pipelines. Unlike probes that require a cable support for active deployment, this probe can be manually lowered and raised by the cable due to its superior strength rating. It is suitable for installation in open moving waters; rivers, streams, ditches (farmland drainage), conveyance canals, and more. In these cases protecting the probe from debris is important. The HI7609829 may be deployed in open waters; monitoring lakes, ponds, wetland basin, infiltration basins, and bays and is suitable for measurements in a flow cell.
Multiparameter, Waterproof, Portable, Logging, GPS, pH, ISE, ORP, EC, Conductivity, TDS, Salinity, Resistivity, DO, Dissolved Oxygen, Turbidity, Temperature, Ammonium, Chloride, Nitrate, USB, Calibration, Probe, Sensors, Environmental Monitoring, Laboratory Testing, Field Testing, Hanna Instruments HI9829.
Product Name | Waterproof Multiparameter Meter for pH / ISE / EC / DO / Turbidity with GPS Option - HI 9829 |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | Automatic at one, two or three points with automatic recognition of five standard solutions (pH 4.01, 6.86, 7.01, 9.18, 10.01) or a custom standard |
ORP Range | ±2000 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | Automatic at one custom point (relative mV) |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
EC Range | 0 to 200 mS/cm (Absolute EC up to 400 mS/cm) |
EC Resolution | Manual: 1 µS/cm: 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm; Automatic: 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm |
EC Accuracy | ± 1% of reading or ± 1 µS/cm, whichever is greater |
EC Calibration | Automatic at a single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point |
TDS Range | 0 to 400000 ppm (mg/L); (maximum value depends on TDS factor) |
TDS Resolution | Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01 g/l (ppt); 0.1 g/L (ppt); 1 g/L (ppt); Automatic: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) |
TDS Accuracy | ± 1% of reading or ± 1 ppm (mg/L), whichever is greater |
TDS Calibration | Based on conductivity or salinity calibration |
Salinity Range (PSU) | 0.00 to 70.00 PSU |
Salinity Resolution (PSU) | 0.01 PSU |
Salinity Accuracy (PSU) | ± 2% of reading or ± 0.01 PSU whichever is greater |
Salinity Calibration (PSU) | Based on conductivity calibration |
Salinity Range (Seawater Sigma) | 0.0 to 50.0 σt, σ₀, σ₁₅ |
Salinity Resolution (Seawater Sigma) | 0.1 σt, σ₀, σ₁₅ |
Salinity Accuracy (Seawater Sigma) | ±1 σt, σ₀, σ₁₅ |
Salinity Calibration (Seawater Sigma) | Based on conductivity or salinity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution | Dependent on resistivity reading |
Resistivity Calibration | Based on conductivity calibration |
Dissolved Oxygen Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Dissolved Oxygen Resolution | 0.1%; 0.01 ppm (mg/L) |
Dissolved Oxygen Accuracy | 0.0 to 300.0 % : ± 1.5 % of reading or ± 1.0 % whichever is greater; 300.0 to 500.0 %: ± 3 % of reading; 0.00 to 30.00 ppm: ± 1.5 % of reading or 0.10 ppm, whichever is greater; 30.00 ppm to 50.00 ppm : ± 3 % of reading |
Dissolved Oxygen Calibration | Automatic at one or two points at 0 and 100% or a custom point |
Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU, 1 FNU from 100 to 1000 FNU |
Turbidity Accuracy | ± 0.3 FNU or ± 2% of reading, whichever is greater |
Turbidity Calibration | Automatic at 1, 2 or 3 points at 0, 20 and 200 FNU, or custom |
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | Automatic at one custom point |
Temperature Compensation | Automatic from -5 to 55 °C (23 to 131 °F) |
Ammonium Range | 0.02 to 200.0 ppm (as NH4+-N) |
Ammonium Resolution | 0.01 ppm to 1 ppm, 0.1 ppm to 200.0 ppm |
Ammonium Accuracy | ± 5% of reading or 2 ppm |
Ammonium Calibration | 1 or 2 points, 10 ppm and 100 ppm |
Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
Chloride Resolution | 0.01 ppm to 1 ppm, 0.1 ppm to 200.0 ppm |
Chloride Accuracy | ± 5% of reading or 2 ppm |
Chloride Calibration | 1 or 2 points, 10 ppm and 100 ppm |
Nitrate Range | 0.62 to 200.0 ppm Ni (as NO3--N) |
Nitrate Resolution | 0.01 ppm to 1 ppm, 0.1 ppm to 200 ppm |
Nitrite Accuracy | ± 5% of reading or 2 ppm |
Nitrate Calibration | 1 or 2 points, 10 ppm and 100 ppm |
Log Memory | 44,000 records (continuous logging or on-demand for all parameters) |
Storage Interval | One second to three hours |
USB Connectivity | With HI929829 software |
Battery Type/Duration | Rechargeable batteries, size C 1.2V NiMH (4); Up to 140 hours depending on configuration |
IP Protection | IP67 |
Environment | 0 to 50°C (32 to 122°F); Max RH 100% |
Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
Weight | 750 g (26.5 oz.) |
GPS | 12-channel receiver with 10 m (30 ft) accuracy |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ± 3 mm Hg within ± 15% from calibration point |
Atmospheric Pressure Calibration | Automatic at one custom point |
Ver todos os detalhes do produto »
$ 1,770.99 USD
It is a portable multiparametric meter with waterproof logging capability that monitors up to 12 water quality parameters, 6 measured and 6 calculated. The multisensor probe with a microprocessor allows measurement of key parameters such as pH, ORP, conductivity, dissolved oxygen, and temperature. The probe digitally transmits readings to the meter, where data points can be displayed and recorded. The use of digital communication enables noise-free data transfer up to a length of 100 meters. The complete system is easy to set up and user-friendly.
The meter features a backlit dot matrix display with on-screen graphics and the ability to automatically adjust digit sizes based on the number of selected parameters. Each measured parameter is fully configurable.
Designed to withstand demanding environments, it is the ideal solution for field measurements in lakes, rivers, and oceans. The meter complies with IP67 standards, and the multisensor probe complies with IP68 standards.
Instrument Specifications | ||
---|---|---|
pH / mV |
Range |
0.00 to 14.00 pH / ±600.0 mV |
Resolution |
0.01 pH / 0.1 mV |
|
Accuracy |
±0. 02 pH / ±0. 5 mV |
|
Calibration |
Automatic one, two, or three points with automatic recognition of five standard solutions (pH 4.01, 6.86, 7.01, 9.18, 10.01) or a custom value |
|
ORP |
Range |
±2000.0 mV |
Resolution |
0.1 mV |
|
Accuracy |
±1.0 mV |
|
Calibration |
Automatic single point custom (relative mV) |
|
EC (Electrical Conductivity) |
Range |
0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) |
Resolution |
Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; Auto-range: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; Auto-range (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
|
Accuracy |
±1% of reading or ±1 µS/cm, whichever is greater |
|
Calibration |
Automatic single point with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point |
|
TDS (Total Dissolved Solids) |
Range |
0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor) |
Resolution |
Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L);
0.01 ppt (g/L) from 10.00 to 99.99ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
|
Accuracy |
±1% of reading or ±1 ppm (mg/L), whichever is greater | |
Calibration |
Based on the electrical conductivity calibration | |
Resistivity |
Range |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resolution |
Depends on the resistance reading |
|
Calibration |
Based on electrical conductivity calibration |
|
Salinity |
Range |
0.00 to 70.00 PSU |
Resolution |
0.01 PSU |
|
Accuracy |
±2% of reading or ±0.01 PSU, whichever is greater |
|
Calibration |
based on electrical conductivity calibration |
|
Seawater Σ |
Range |
0.0 to 50.0 Σt, Σ₀, Σ₁₅ |
Resolution |
0.1 Σt, Σ₀, Σ₁₅ |
|
Accuracy |
±1 Σt, Σ₀, Σ₁₅ |
|
Calibration |
based on electrical conductivity calibration |
|
Dissolved Oxygen |
Range |
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Resolution |
0.1%; 0.01 ppm (mg/L) |
|
Accuracy |
0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading |
|
Calibration |
Automatic at one or two points at 0% and 100% or a custom point |
|
Atmospheric Pressure |
Range |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Resolution |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
|
Accuracy |
±3 mm Hg at ±15°C temperature during calibration |
|
Calibration |
Automatic at a custom point |
|
Temperature |
Range |
-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to K 328.15 |
Resolution |
0.01°C; 0.01°F; 0.01 K |
|
Accuracy |
±0.15°C; ±0.27°F; ±0.15K |
|
Calibration |
Automatic at a custom point |
|
Additional Specifications |
Temperature Compensation |
Automatic from -5 to 55°C (23 to 131°F) |
Memory Logging |
45,000 logs (continuous or on-demand logging of all parameters) |
|
Logging Interval |
one second to three hours |
|
PC Connectivity |
USB for PC with Hanna HI9298194 software |
|
Environment |
0 to 50°C (32 to 122°F); HR 100% IP67 |
|
Battery Type / Life |
1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) |
|
Dimensions / Weight |
185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4") / 400 g (14.2 oz.) |
Probe Specifications | ||
---|---|---|
Probe |
HI7698194 |
|
Sensors |
3 (pH, DO, EC) |
|
Environmental Samples |
Freshwater, brackish, seawater |
|
Protection |
IP68 |
|
Operating Temperature |
-5 to 55°C |
|
Storage Temperature |
-20 to 70°C |
|
Maximum Depth |
20 m (66') |
|
Dimensions (without cable) |
342 mm (13.5 inches); diameter 46 mm (1.8 inches) |
|
Weight (without batteries and sensors) |
570 g (20.1 oz.) |
|
Cable Specification |
Multi-conductor shielded cable with internal junction rated for use up to 68 kg (150 lb). Intermittent use |
|
Materials for Moisture |
Body |
ABS |
Threaded Fittings |
Nylon |
|
Guard |
ABS / 316 SS |
|
Temperature Probe |
316 SS |
|
O-rings |
EPDM |
Sensor Specifications | |||||
---|---|---|---|---|---|
Sensor |
HI7698194-0 |
HI7698194-1 |
HI7698194-3 |
HI7698194-2 |
|
Description |
pH Sensor |
pH/ORP Sensor |
EC Sensor |
OD Sensor |
|
Measurement Type |
pH, pH-mV |
pH, pH-mV, ORP |
EC, TDS, salinity |
OD (% saturation and |
|
Measurement Range |
0.00 to 13.00 pH; ±600.0 pH-mV |
pH from 0.00 to 13.00; ±600.0 pH mV; ±2000.0 mV (ORP) |
0.0 to 200.0 mS/cm; (absolute) |
0.0 to 500.0%; |
|
Temperature Range |
-5 to 55 °C |
-5 to 55 °C |
-5 to 55 °C |
-5 to 55 °C |
|
Color Code |
Red |
Red |
Blue |
White |
|
Materials |
Tip (pH) |
Glass (pH) |
Glass (pH); Pt (ORP) |
Stainless Steel AISI 316 |
Cat / an: Ag/Zn |
Junction |
Ceramic |
Ceramic |
N/A |
High-Density Polyethylene Membrane |
|
Body |
PEI |
PEI |
ABS/epoxy |
White ABS tip |
|
Electrolyte |
Gel |
Gel |
N/A |
N/A |
|
Reference |
Double |
Double |
N/A |
N/A |
|
Maintenance Solution |
HI70300 (Storage Solution) |
HI70300 (Storage Solution) |
None |
HI7042S (Electrolyte) |
|
Dimensions |
118 x 15 mm |
118 x 15 mm |
111 x 17 mm |
99 x 17 mm |
|
Maximum Depth |
20 m (65') |
20 m (65') |
20 m (65') |
20 m (65') |
EO 20230831
Ver todos os detalhes do produto »
Request Quote
The HI1332D pH Electrode with Special DIN Connection is designed to provide accurate and stable measurements in a wide range of chemical, field, and quality control applications. Its double junction reference, durable PEI body, and spherical tip design make it ideal for demanding environments. This electrode is compatible with pH meters that incorporate the CAL CHECK system, offering a robust solution for users who require reliable data with low maintenance.
Specification | Details |
---|---|
Reference | Double, Ag/AgCl |
Junction / Flow | Single ceramic / 15-20 μL/h |
Electrolyte | KCl 3.5M |
Maximum Pressure | 0.1 bar |
pH Range | 0 to 13 |
Operating Temperature | 20 to 40 °C (68 to 104 °F) |
Tip / Shape | Spherical (Ø 7.5 mm) |
Temperature Sensor | No |
Amplifier | No |
Body Material | PEI |
Cable | Coaxial; 1 m (3.3') |
Connection | Special DIN with screw-type metal banana connector |
Compatibility | pH meters with CAL CHECK system (not compatible with models using a threaded cap) |
Ver todos os detalhes do produto »
Request Quote
The HI98594 is a portable multiparameter logging system (meter and probe) that monitors up to 14 different water quality parameters (7 measured and 7 calculated), such as pH, ORP, turbidity, conductivity, dissolved oxygen, and temperature. The HI98594 features a backlit graphic display that automatically adjusts the digit size to fit the screen and allows on-screen graphing. Each parameter is fully configurable.
The HI98594 is designed to withstand harsh environmental conditions and is ideal for field measurements. The meter meets the IP67 standard (30 minutes immersion at a depth of 1 m) and the multisensor probe is fully sealed against water and dust, meeting the IP68 standard (continuous immersion in water). The meter incorporates a dual charging system, using a rechargeable lithium battery and backup alkaline batteries to extend its use in the field.
The meter can log data that is easily downloaded as a CSV file or graph using Bluetooth® wireless technology for the Hanna Lab app on iOS and Android devices, or to a PC via a USB type A to C cable.
The HI98594 can display 1 to 14 parameters on its high-contrast backlit LCD screen. pH, EC (electrical conductivity), and dissolved oxygen (DO) measurements are automatically compensated for temperature variations. Additionally, dissolved oxygen concentration measurements are automatically compensated for barometric pressure and salinity.
The HI98594 allows logging a single data point or performing continuous logging at selected time intervals. All logs can be stored in a named batch and allow adding observations. These functions facilitate the collection of meaningful data, including notes on local environmental conditions.
The meter operates with a built-in lithium-ion battery. When the rechargeable battery is depleted, the meter automatically switches to 1.5 V AA alkaline batteries.
The Quick Calibration function allows for a quick one-point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are also available, including:
Calibration information is logged along with a timestamp and date. This includes calibration values and other relevant data that may affect measurements. GLP data is stored along with the logged data.
Bluetooth® 5.0 Connectivity and Hanna Lab App Compatibility
The HI98594 allows wireless connection with smart devices via the Hanna Lab App. Through the app, log batches can be emailed or downloaded for review.
Logs can be shared as .CSV or PDF files.
Complete GLP (Good Laboratory Practice) data can be reviewed for all parameters when the logged data is downloaded to a smart device.
When reviewing data on a smart device, there is an option to select the measurement units to be displayed regardless of the meter's configuration.
For trend analysis, the Hanna Lab App offers the option to graph the logged data.
The HI7698594 is delivered with pre-installed sensors for pH/ORP, EC/Turbidity, and optical dissolved oxygen.
Sensor replacement is quick and easy thanks to field-replaceable screw-type connectors, color-coded for easy identification. These meters automatically recognize the connected sensors.
The optical dissolved oxygen sensor uses a smart cap that features an RFID tag that stores unique calibration coefficients for each cap. The RFID tracks the cap's lifespan and alerts the user when it needs to be replaced.
Parameter | Range | Resolution | Accuracy | Calibration |
pH / mV | 0.00 to 14.00 pH* / ±600.0 mV | 0.01 pH / 0.1 mV | ±0.02 pH / ±1.2 mV |
|
ORP | ±2000.0 mV | 0.1 mV | ±1.0 mV | Automatic at a custom point (relative mV). |
Dissolved Oxygen | 0.0 to 500.0 % saturation 0.00 to 50.00 ppm (mg/L) |
0.1 % saturation 0.01 ppm (mg/L) |
|
|
Pressure Compensation | Automatic from 450 to 850 mmHg |
Parameter | Range | Resolution | Accuracy | Calibration |
EC | 0 to 200 mS/cm 0 to 400 mS/cm (absolute) |
|
±1 % of reading or ±1 μS/cm, whichever is greater |
|
Resistivity | 0 to 999999 Ω·cm 0 to 1000.0 kΩ·cm 0 to 1.0000 MΩ·cm |
1 Ω·cm 0.1 kΩ·cm 0.0001 MΩ·cm |
- | Based on conductivity calibration |
Parameter | Range | Resolution | Accuracy | Calibration |
TDS | 0 to 400000 ppm (mg/L) (maximum value depends on TDS factor) |
|
±1 % of reading or ±1 ppm (mg/L), whichever is greater | Based on conductivity or salinity calibration |
Salinity | 0.00 to 70.00 PSU | 0.01 PSU | ±2 % of reading or ±0.01 PSU, whichever is greater | One point using a custom solution |
Seawater Sigma | 0.0 to 50.0 σt, σ0, σ15 | 0.1 σt, σ0, σ15 | ±1.0 σt, σ0, σ15 | Based on conductivity or salinity calibration |
Turbidity | 0.0 to 99.9 FNU 100 to 1000 FNU |
|
±0.3 FNU or ±2 % of reading, whichever is greater | Automatic, up to three points using 0 FNU, 20 FNU, 200 FNU, or a custom solution |
Parameter | Range | Resolution | Accuracy | Calibration |
Atmospheric Pressure | 450.0 to 850.0 mmHg 17.72 to 33.46 inHg 600.0 to 1133.2 mbar |
0.1 mmHg 0.01 inHg 0.1 mbar |
±3.0 mmHg within ±15 °C from calibration temperature | Automatic at a custom point |
Temperature | −5.00 to 50.00 °C 23.00 to 122.00 °F 268.15 to 323.15 K |
0.01 °C 0.01 °F 0.01 K |
±0.15 °C ±0.27 °F ±0.15 K |
Automatic at a custom point |
Temperature Compensation | Automatic | |||
Logging Memory |
|
|||
Logging Interval | From 1 second to 3 hours | |||
USB-C Functions (Host) | Mass storage host | |||
USB-C Functions (Device) | Mass storage device | |||
Protection | IP67 | |||
Environment | 0 to 50 °C (32 to 122 °F); RH 100 % | |||
Battery Type | 4 AA 1.5 V alkaline batteries 1 internal rechargeable lithium-ion battery |
|||
Battery Life | ≈ 126 hours 90 hours using AA alkaline batteries 36 hours using lithium-ion battery** |
|||
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) | |||
Weight | 435 g (13.3 oz) |
Sensor Inputs | 3 (pH or pH/ORP, EC or EC/Turbidity, DO) |
Sample Environment | Fresh, brackish, and seawater |
Waterproof Protection | IP68 |
Operating Temperature | −5.0 to 50.0 °C 23.0 to 122.0 °F |
Storage Temperature | −20.0 to 70.0 °C −4.0 to 158.0 °F |
Maximum Depth | 20 m (66’) |
Dimensions (without cable) | Length: 342 mm (13.5”) Diameter: 46 mm (1.8”) |
Weight (without sensors) | 570 g (20.1 oz) |
Ver todos os detalhes do produto »