SHIPPING QUOTE FOR OVERSIZED ITEMS MUST BE REQUESTED | WhatsApp Global CLICK HERE

Campbell Scientific CR1000Xe Data Logger for Measurement and Control

Ref: CASC-CR1000XE-P03

  • Last Price Update: (?)
  • If the item is in US stock, the estimated *Processing Time before shipping is: 5-9 business days. ¿Require Priority Shipping? Let us know to check if it is possible.
    *Processing Time = Preparation, Production, or Importation

  • Coleções: Data Loggers

    Vendedor: Campbell Scientific


    Shipping Weight: 2.4 lb


    Outstanding Performance

    Enhanced with additional serial ports, power control, and MQTTS for Meteorological Data Management Systems such as CampbellCloud™

    Required Items! 12 VDC power supply

    The CR1000Xe datalogger performs measurements and control tasks for a wide variety of applications. Its reliability and robustness make it an excellent choice for remote environmental applications, including hydrology and meteorology stations (HydroMet), solar resource assessment and monitoring (SRA/SRM), dams and mines (geotech), and broad research objectives related to environmental systems.

    The CR1000Xe is a low-power device that measures analog and digital sensor signals, processes and stores the measurements, and adapts to any type of telecommunications link. It stores data and programs in non-volatile flash memory. The integrated programming language—common to all Campbell Scientific dataloggers—allows users to create solutions perfectly tailored to the application.


    Features

    • Operates in extreme conditions, standard range from -40°C to +70°C, and optional extended range from -55°C to +85°C.
    • Direct connection to computer USB port.
    • High analog signal sampling speed of over 300Hz.
    • High resolution in analog voltage measurements via 24-bit A/D converter.
    • Includes two dedicated measurement channels for 0-20 mA or 4-20 mA signals.
    • CPI port for connecting high-speed distributed CDM modules (such as GRANITE™ series modules).
    • RJ45 Ethernet port.
    • MicroSD card slot for memory expansion.
    • Serial communications with devices and sensors via SDI-12, RS-232, and/or RS-485.
    • Supports PakBus routing.
    • Embedded web page.
    • Power supply from 10 to 36 Vdc.
    • Regulated 12 Vdc power output.
    • Power control on CS I/O port for external modems.

    The electronics of the CR1000Xe are protected from external radio frequency by a sealed stainless steel enclosure. It includes a low-drift clock safeguarded by a battery that can be synchronized via NTP, GPS, and Campbell Scientific PakBus®. The enclosure and connection panel are joined by stainless steel connectors. The pins in the CPI and Ethernet ports are gold-plated to resist corrosion. The CR1000Xe is compatible with 12 V and 24 V nominal power systems. The datalogger's connection panel regulates the 12 V outputs and includes two switchable 12 V outputs on removable terminal blocks and one switchable 12 V output on the datalogger's CS I/O port.

    Compatibility

    Note: The following shows notable compatibility information. It is not a list of all compatible products.

    Sensors

    Product Compatible Note
    FW05 The CR1000Xe is compatible when used with the CDM-A108 or CDM-A116.
    FW1 The CR1000Xe is compatible when used with the CDM-A108 or CDM-A116.
    FW3 The CR1000Xe is compatible when used with the CDM-A108 or CDM-A116.

    Communication Devices

    Product Compatible Note
    CD295 Contact Campbell Scientific for assistance.

    Software

    Product Compatible Note
    DevConfig
    KonectGDS
    LoggerLink
    LoggerNet
    PC400
    RTDAQ
    RTMCPRO
    Short Cut

    Additional Compatibility Information

    Sensors

    Given the variety of its channel functions, the CR1000Xe is compatible with almost any sensor, including analog (voltage and current), serial, thermocouples, SDI-12, pulse, and frequency.

    Measurement and Control Peripherals

    The CR1000Xe is compatible with all our multiplexers, vibrating wire interfaces, TIM modules, and relays.

    Communications

    The CR1000Xe communicates directly with a computer via USB port, 10/100 Base-T Ethernet port, mobile telephony, radio, and satellite transmitters (HDR GOES, Argos, Meteosat, Iridium, and Inmarsat).

    Data can be viewed locally using Campbell Scientific software for Windows, iOS or Android devices. Additionally, with CR1000KD, CD100, and CD295 display keyboards.

    Enclosures

    The CR1000Xe and its power supply can be housed in any of our standard enclosures.

    Power Supply

    The CR1000Xe datalogger can be powered with any 12V or 24V DC source. The most commonly used power supplies with the CR1000Xe are the PS150 and PS200.

    Software

    Campbell Scientific software is available to program, configure, and communicate with the CR1000Xe datalogger. Several software options are available including PC400, LoggerNet, CampbellCloud™, and CampbellGo™. Consult with our sales engineers to determine the best software or cloud option.



    • Operating Temperature Range
      • -40° to +70°C (standard)
      • -55° to +85°C (extended)
      • Non-condensing environment
      Maximum Sampling Rate 1000 Hz
      Connection Panel Material Anodized aluminum
      Analog Inputs 16 single-ended or 8 differential (individually configurable). Two analog inputs can measure 4 to 20 mA or 0 to 20 mA signals.
      Pulse Counters 10 (P1 to P2 and C1 to C8)
      Voltage Excitation Terminals 4 (VX1 to VX4)
      Maximum Current
      • ±40 mA (voltage excitation)
      • 50 mA (regulated 3.3 or 5 V)
      Communication Ports
      • USB-C
      • Ethernet
      • RS-232
      • RS-485
      • RS-422
      • CS I/O
      • CPI
      Storage Slot microSD
      12 Vdc Output 2 terminals, plus pin 8 on CS I/O port
      Digital I/O 8 terminals (C1 to C8) configurable for digital inputs/outputs. Includes high/low state, pulse width modulation, external interrupt, edge timing, contact closure pulse counting, high-frequency pulse counting, UART, RS-232, RS-485, SDM, SDI-12, I2C, and SPI serial communication functions. Terminals configurable in pairs for 5 V or 3.3 V logic in some functions.
      Input Range ±5 V
      Analog Voltage Measurement Accuracy
      • Accuracy specifications do not include sensor or measurement noise.
      • ±(0.04% of reading + offset) from 0° to 40°C
      • ±(0.06% of reading + offset) from -40° to +70°C
      • ±(0.08% of reading + offset) from -55° to +85°C (extended temperature range)
      ADC 24-bit
      Power Requirements 10 to 36 Vdc input
      Real-Time Clock Accuracy ±3 min. per year (optional with GPS correction ±10 µs)
      Internet Protocols Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP, MQTT(S)
      Communication Protocols CPI, PakBus, SDM, SDI-12, Modbus, TCP, DNP3, UDP, NTCIP, NMEA 0183, I2C, SPI, CampbellCloud HTTPS/MQTTS, and others
      SRAM Memory with Battery Backup for CPU and Data Storage 4 MB
      Data Storage 4 MB SRAM + 72 MB flash (expandable up to 16 GB with removable microSD flash card)
      Average Current Consumption 1.1 mA (1 Hz scan @ 24 Vdc)
      Average Current Consumption 2 mA (1 Hz scan @ 12 Vdc)
      Average Standby Current Consumption
      • < 2.0 mA (@ 12 Vdc)
      • 57 mA (20 Hz scan @ 12 Vdc)
      Dimensions 23.8 x 10.1 x 6.2 cm (9.4 x 4.0 x 2.4 in.)
      Additional clearance required for cables and wires
      Weight 0.86 kg (1.9 lb)

      • 4x 505. Screw #6-32 x .375 Pan Phillips
      • 4x 6044. Eyelet for screw #6 or #8
      • 1x 8125. Flat blade screwdriver, 2.5 mm x 50 mm blade
      • 1x 3315. Type T thermocouple
      • 1x 38790. USB Type C to Type A cable, 6/6.5 ft
      • 1x 33298. CR1000Xe Quick Start Card
      • 1x 31910. Default datalogger program

      • Power supply: A 12 VDC power supply, such as a battery, is needed if not powered via USB, especially for field deployments.
      • Computer: A computer with a USB port for initial connection and programming.
      • Support software: A program for the datalogger, such as Short Cut, LoggerNet, PC200W, or PC400W, to create programs, configure, and collect data.
      • Datalogger program: A program loaded into the datalogger to perform measurements, store data, or control external devices.

      • Sensors: The CR1000Xe is compatible with a wide variety of sensors, including analog, thermocouples, serial, SDI-12, pulse, and frequency sensors.
      • Measurement and control peripherals: Expansion modules such as CDMs, multiplexers, vibrating wire interfaces, terminal input modules, and relays.
      • Communications: Multipoint modems, short-range modems, telephone modems (landline, digital cellular, voice synthesizer), RF telemetry, and satellite transmitters.
      • Displays:
        • CR1000KD Keyboard/Display
        • CD100 Panel Mount Display with Keyboard
        • iOS or Android devices (requires free LoggerLink app)
        • CD295 DataView II Display
      • Enclosures: Any standard Campbell Scientific enclosure to house the CR1000Xe and its power supply.
      • Additional power supplies: Other Campbell Scientific power supply models, such as BPALK, PS150, and PS200.
      • microSD card: Recommended for extended memory requirements. Industrial microSD cards of 2 GB or 16 GB are suggested.
      • Insulated terminal cover: To improve thermocouple measurement accuracy.
      • Cables: Specific cables such as CPI/RS-232 RJ45 to DB9 (male) and CAT6/CAT5e Ethernet cables.
      • Terminal connectors: Connectors such as the 5-position lever nut connector.
      • Desiccant bag: For internal humidity control.

    • Product Brochures

      Manuals

      Technical Documents

      Compliance