    Advanced Waterproof Multiparameter Meter with GPS for Water Quality Monitoring - HI9829

    High-precision portable device that measures up to 14 water quality parameters, with integrated GPS option, ideal for environmental, field, and laboratory applications.

    The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

    • Optional GPS provides location tracking of measurements.
    • Color coded, field replaceable sensors.
    • Great for environmental, field, and laboratory testing.

    Built-in GPS Receiver

    • 12 channel GPS receiver and antenna.
    • Tracks location using satellites to within 30 feet.
    • Latitude and longitude recorded with readings.
    • Location naming for GPS coordinates.
    • Distance from current location to the stored location.
    • Hi929829 multiparameter water quality meter software supplied integrates data collected with *Google™ maps.
    • Measurement readings including GPS coordinates, date and time, named locations and remarks sample number.

    *Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.

     

    Two probes to choose from (Basic or Logging)

    The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default, the HI9829 and the corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

    HI7609829 Basic Probe

    HI7629829 Autonomously Logging Probe

    • Digital probe that is less than 2 inches in diameter.
    • 3 color-coded sensor inputs.
    • IP68 rating for continuous immersion in water.
    • Multistrand –multiconductor cable rated for 150 lbs (intermittent use).
    • Available with 4, 10, or 20-meter cable.
    • Weighted shield protects all sensors.
      • Same as basic probe but with logging capability.
      • Logs data independent of HI9829 meter.
      • Operates on 4 “AA” batteries for up to 70 days*.
      • Stores up to 140,000 single parameter readings or 35,000 for all parameters.
      • Logs data from 1 second to 3 hours.
      • Choose to be supplied with EC or EC/Turbidity sensor.
      • Supplied with USB cable for direct connection to Window’s compatible PC.

      *All channels logging at 10-minute intervals with no averaging.

    The HI7609829  (logging) is a multiparameter pH/ISE/EC/DO/Turbidity/Temperature probe for use with the HI9829 portable meter. Sensors are automatically recognized by the probe and meter when connected. Sensor replacement is quick and easy with field replaceable, screw type connectors that are color-coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, and 20m lengths available. It’s rugged, waterproof design makes it ideal for field use. The probe is suitable for installation in confined locations such as air vaults, river intakes, vertical wells, tanks, etc.. The streamline diameter of the probe permits insertion into 2" pipelines. Unlike probes that require a cable support for active deployment, this probe can be manually lowered and raised by the cable due to its superior strength rating. It is suitable for installation in open moving waters; rivers, streams, ditches (farmland drainage), conveyance canals, and more. In these cases protecting the probe from debris is important. The HI7609829 may be deployed in open waters; monitoring lakes, ponds, wetland basin, infiltration basins, and bays and is suitable for measurements in a flow cell.

    Product Name Waterproof Multiparameter Meter for pH / ISE / EC / DO / Turbidity with GPS Option - HI 9829
    pH Range 0.00 to 14.00 pH
    pH Resolution 0.01 pH
    pH Accuracy ±0.02 pH
    pH Calibration Automatic at one, two or three points with automatic recognition of five standard solutions (pH 4.01, 6.86, 7.01, 9.18, 10.01) or a custom standard
    ORP Range ±2000 mV
    ORP Resolution 0.1 mV
    ORP Accuracy ±1.0 mV
    ORP Calibration Automatic at one custom point (relative mV)
    mV Range ±600.0 mV
    mV Resolution 0.1 mV
    mV Accuracy ±0.5 mV
    EC Range 0 to 200 mS/cm (Absolute EC up to 400 mS/cm)
    EC Resolution Manual: 1 µS/cm: 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm; Automatic: 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm
    EC Accuracy ± 1% of reading or ± 1 µS/cm, whichever is greater
    EC Calibration Automatic at a single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point
    TDS Range 0 to 400000 ppm (mg/L); (maximum value depends on TDS factor)
    TDS Resolution Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01 g/l (ppt); 0.1 g/L (ppt); 1 g/L (ppt); Automatic: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
    TDS Accuracy ± 1% of reading or ± 1 ppm (mg/L), whichever is greater
    TDS Calibration Based on conductivity or salinity calibration
    Salinity Range (PSU) 0.00 to 70.00 PSU
    Salinity Resolution (PSU) 0.01 PSU
    Salinity Accuracy (PSU) ± 2% of reading or ± 0.01 PSU whichever is greater
    Salinity Calibration (PSU) Based on conductivity calibration
    Salinity Range (Seawater Sigma) 0.0 to 50.0 σt, σ₀, σ₁₅
    Salinity Resolution (Seawater Sigma) 0.1 σt, σ₀, σ₁₅
    Salinity Accuracy (Seawater Sigma) ±1 σt, σ₀, σ₁₅
    Salinity Calibration (Seawater Sigma) Based on conductivity or salinity calibration
    Resistivity Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
    Resistivity Resolution Dependent on resistivity reading
    Resistivity Calibration Based on conductivity calibration
    Dissolved Oxygen Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
    Dissolved Oxygen Resolution 0.1%; 0.01 ppm (mg/L)
    Dissolved Oxygen Accuracy 0.0 to 300.0 % : ± 1.5 % of reading or ± 1.0 % whichever is greater; 300.0 to 500.0 %: ± 3 % of reading; 0.00 to 30.00 ppm: ± 1.5 % of reading or 0.10 ppm, whichever is greater; 30.00 ppm to 50.00 ppm : ± 3 % of reading
    Dissolved Oxygen Calibration Automatic at one or two points at 0 and 100% or a custom point
    Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
    Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU, 1 FNU from 100 to 1000 FNU
    Turbidity Accuracy ± 0.3 FNU or ± 2% of reading, whichever is greater
    Turbidity Calibration Automatic at 1, 2 or 3 points at 0, 20 and 200 FNU, or custom
    Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
    Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F
    Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
    Temperature Calibration Automatic at one custom point
    Temperature Compensation Automatic from -5 to 55 °C (23 to 131 °F)
    Ammonium Range 0.02 to 200.0 ppm (as NH4+-N)
    Ammonium Resolution 0.01 ppm to 1 ppm, 0.1 ppm to 200.0 ppm
    Ammonium Accuracy ± 5% of reading or 2 ppm
    Ammonium Calibration 1 or 2 points, 10 ppm and 100 ppm
    Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
    Chloride Resolution 0.01 ppm to 1 ppm, 0.1 ppm to 200.0 ppm
    Chloride Accuracy ± 5% of reading or 2 ppm
    Chloride Calibration 1 or 2 points, 10 ppm and 100 ppm
    Nitrate Range 0.62 to 200.0 ppm Ni (as NO3--N)
    Nitrate Resolution 0.01 ppm to 1 ppm, 0.1 ppm to 200 ppm
    Nitrite Accuracy ± 5% of reading or 2 ppm
    Nitrate Calibration 1 or 2 points, 10 ppm and 100 ppm
    Log Memory 44,000 records (continuous logging or on-demand for all parameters)
    Storage Interval One second to three hours
    USB Connectivity With HI929829 software
    Battery Type/Duration Rechargeable batteries, size C 1.2V NiMH (4); Up to 140 hours depending on configuration
    IP Protection IP67
    Environment 0 to 50°C (32 to 122°F); Max RH 100%
    Dimensions 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
    Weight 750 g (26.5 oz.)
    GPS 12-channel receiver with 10 m (30 ft) accuracy
    Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
    Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
    Atmospheric Pressure Accuracy ± 3 mm Hg within ± 15% from calibration point
    Atmospheric Pressure Calibration Automatic at one custom point
    • 1x HI 710140 Hard Case.
    • 1x HI 7612 VDC Adapter.
    • 1x HI 7698292 Probe Maintenance Kit.
    • 1x HI 929829 PC Application Software.
    • 1x HI 7698291 USB Cable (PC to meter).
    • 1x HI 710045 Power Cable.
    • 1x HI 710046 Cigarette Lighter Power Cable.
    • 1x HI9829-25 Quick Calibration Solution.
    • 1x HI 920005 iButton with holder.
    • 1x HI7609829-1 pH/ORP Sensor.
    • 1x HI 7609829-2 Galvanic DO Sensor.
    • 1x HI 7609829-3 EC Sensor.
    • 1x HI 7698290 Short Calibration Beaker.
    • 1x HI7698295 Short Weighted Guard.
    • 1x NiMH "C" Rechargeable Batteries.
    • 1x 12VDC Power Adapter.
    • 1x Instruction Manual.