SHIPPING QUOTE FOR OVERSIZED ITEMS MUST BE REQUESTED | WhatsApp Global CLICK HERE
$ 699.95 USD
This product is sold by BIOWEB United States just for delivery in US. This line...
$ 799.00 USD
This product is sold by BIOWEB United States just for delivery in US. A rugged...
$ 522.00 USD
This product is sold by BIOWEB United States just for delivery in US. All the...
$ 127.99 USD
Plant tissue testing provides essential information concerning plant use of nutrients vital to their growth....
$ 186.75 USD
The BrewLab® Basic test kit for home brewers monitors 7 essential water quality factors. Experts agree that the quality of the water that you start with will affect your final product, so take the mystery out of making great tasting beer.
The BrewLab® Plus test kit for Home Brewers quantifies 8 essential test factors. Included is a digital pH meter for monitoring batches from start to finish.
The BrewLab® Pro water analysis kit. Designed with the professional brewer in mind, this kit measures 11 test factors which are important in the brewing process. Water is the most important ingredient for any brewer. The BrewLab® Pro helps you to make your best craft brew and reproduce your results time and time again!
Experts agree water conditions affect your final product, so take the mystery out of making great beer. Trust LaMotte, the water analysis experts since 1919, to help you control your most important ingredient... water!
Ship Code: (R1) Small Quantity Hazardous Material - No Fees Applicable 🟢
Test Factor | BrewLab Pro | BrewLab Plus | BrewLab Basic | Test System | Range | # of Tests |
Chloride | ![]() |
![]() |
![]() |
Direct Reading Titrator | 1 drop = 10, 25 ppm | Approx. 80 |
Sulfate | ![]() |
![]() |
![]() |
Turbidimetric | 0-200 ppm sulfate | 50 |
Alkalinity | ![]() |
![]() |
![]() |
Direct Reading Titrator | 0-200 ppm (and higher) as CaCO3 | 50 at 200 ppm |
Total Hardness | ![]() |
![]() |
![]() |
Direct Reading Titrator | 0-200 ppm (and higher) as CaCO3 | 50 at 200 ppm |
Calcium Hardness | ![]() |
![]() |
![]() |
Direct Reading Titrator | 0-200 ppm (and higher) as CaCO3 | 50 at 200 ppm |
Magnesium Hardness | ![]() |
![]() |
![]() |
Calculation | - | - |
Sodium | ![]() |
![]() |
![]() |
Calculation | - | - |
pH | ![]() |
![]() |
Electrometric | 0.0-14.0 pH | - | |
Temperature |
![]() |
Electrometric |
32 to 149°F (0 to 65°C) | - | ||
Total Dissolved Solids |
![]() |
Electrometric |
0 to 99.9 ppm (mg/L), 100 to 999 ppm (mg/L), 1.00 to 9.99 ppt |
- | ||
Dissolved Oxygen (Sat. Mode) |
![]() |
Electrometric | 0 to 200.0% | - | ||
Dissolved Oxygen (Conc. Mode) |
![]() |
Electrometric | 0 to 20.00 ppm (mg/L) | - |
$ 382.00 USD
For use where Secchi disc readings are not feasible. Turbidity is measured by direct comparison...
Request Quote
Cable Management Kit Easily manage your cables. Also attaches to the back of the instrument...
Request Quote
Pro Series Soft Sided Carrying Case A soft-sided carrying case ideal for all Pro Series...
Request Quote
† WARNING: California Proposition 65 🔴 Due to the contents of this product, delivery time...
Request Quote
The kit includes 10 concentrated solutions of macronutrients and trace elements, enough to prepare five liters of each mix. Additionally, a detailed plant nutrition study manual is included.
† California Proposition 65 WARNING: Cancer and reproductive harm for more information go to www.P65Warnings.ca.gov/chemicals
Specification | Details |
---|---|
Shipping Code | (R2) Hazardous Material - Air Rates Apply |
Shipping Weight in kg | 3.18 kg |
$ 545.00 USD
🔴 Due to the content of this product, it has air fees applicable for exportation. This product is sold by BIOWEB Global for US delivery only.
Ideal for examining water quality in known or suspected contaminated aquatic environments.
Specifications | |||
---|---|---|---|
Titration Tests | |||
Test Factor | Range (# Tests) | Kit Codes | Shipping Code |
Dissolved Oxygen | 0-10.0 ppm (50) | 5860-01 | LQ |
Colorimetric Tests | |||
Test Factor | Range (# Tests) | Kit Codes | Shipping Code |
Chlorine | 0.2-3.0 ppm (50) | 3308-01 | NH |
pH | 3-10.5 (100) | 5858-01 | R1 |
Nitrate-Nitrogen | 0.2-1.0 ppm (40) | 3119-01 | R3 |
Phosphate | 0.2-1.0 ppm (50) | 3119-01 | R3 |
Ammonium Nitrogen | 1.0-4.0 ppm (50) | 5864-01 | R1 |
Temperature | -5°C – 45°C | 1066 | NH |
† Proposition 65 WARNING: Cancer and reproductive harm - www.P65Warnings.ca.gov/chemicals
* Shipping Codes. Import Restriction.
(EO 20230828)
Request Quote
🔴 Due to the content of this product, it has air fees applicable for exportation. This product is sold by BIOWEB Global for US delivery only.
This portable lab measures 24 water quality parameters for pollution detection, environmental studies, and industrial water and wastes. The digital SMART® colorimeter analyzes test sample color reactions and provides direct readouts for 15 factors. Titration tests performed with LaMotte's Direct Reading Titrators provide results directly in ppm for 6 additional factors.
Also includes digital meters to measure pH, conductivity, and TDS. The Digital SMART® Colorimeter is programmed to provide direct readouts for over 60 factors using optional reagent packages.
† California Proposition 65 WARNING: Cancer and reproductive harm for more information go to www.P65Warnings.ca.gov/chemicals
Test Factor |
Method | Range | # of Tests |
---|---|---|---|
Ammonia-Nitrogen | Salicylate | 0.05-4.0 ppm | 50 |
Chlorine | DPD | 0.03-4.0 ppm | 100 |
Bromine | DPD | 0.10-9 ppm | 100 |
Iodine | DPD | 0.2-14 ppm | 100 |
Chromium (Hexavalent) | Diphenylcarbohydrazide | 0.01-1.0 ppm | 100 |
Copper | Diethyldithiocarbamate | 0.10-6.0 ppm | 100 |
Fluoride | SPADNS | 0.1-2.0 ppm | 50 |
Iron | Bipyridyl | 0.10-6.0 ppm | 50 |
Nitrate-Nitrogen | Cadmium Reduction | 0.10-3.0 ppm | 20 |
Nitrite-Nitrogen | Diazotization/Coupling | 0.20-0.8 ppm | 20 |
Phosphate | Ascorbic Acid Reduction | 0.05-3.0 ppm | 50 |
Silica | Heteropoly Blue | 0.05-4.0 ppm | 50 |
Sulfate | Barium Chloride | 3-100 ppm | 50 |
Sulfide | Methylene Blue | 0.06-1.50 ppm | 50 |
Turbidity | Absorption (no rgts) | 3-400 NTU | |
Direct Reading Titrator Tests | |||
Test Factor | Method | Range | # of Tests |
Alkalinity | Neutralization | 0-200 ppm | 50 |
Carbon Dioxide | Neutralization | 0-50 ppm | 50 |
Chloride/Salinity | Argentometric | 0-200 ppm | 50 |
Dissolved Oxygen | Winkler Method | 0-10 ppm | 50 |
Hardness (Calcium, Magnesium, & Total) | Complexometric | 0-200 ppm | 50 |
Ship Code: (LQ) Hazardous Material - Air Fees Applicable.
EO20232704
$ 340.00 USD
Available from November 2023
An inquiry-based approach to watershed education. Students ask questions, learn to design and implement a river study from acquiring and reading watershed maps to determining/scheduling study sites and water quality testing. They will then compile and analyze results, share the results with their community, and learn to take action through a variety of productive avenues and disciplines.
A great tool for beginning a school-based, community involved water monitoring program. Includes a valuable, comprehensive manual and a set of 9 test factor modules. Same economical, safe, TesTabs® method as the Earth Force Low Cost Water Monitoring Kit. Each module contains easy-to-read, diagrammed instructions; a color chart; a test factor flashcard; and all the necessary apparatus and non-hazardous TesTabs® to perform 100 tests (44 tests for coliform bacteria; unlimited for benthic macroinvertebrates and turbidity).
Recommended for grades 4 and higher. Also ideal for community groups/citizen monitoring efforts.
🟢 This product has no import restrictions.
Test Factor |
Individual Kit Code |
Ship Code |
---|---|---|
Biochemical Oxygen Demand | 5889 | NH |
Coliform Bacteria | 5850 | NH |
Oxígeno disuelto | 5889 | |
Dissolved Oxygen | 5891 | NH |
pH | 5890 | NH |
Phosphate | 5892 | NH |
Turbidity | 5887 | NH |
Temperature (0-12°C) | 31821 | NH |
Temperature (14-40°C) | 31822 | NH |
EO20230404
$ 56.25 USD
🔴 Due to the content of this product, it has air fees applicable for exportation. This product is sold by BIOWEB Global for US delivery only.
This test kit measures for high chlorine levels using the direct reading titrator method. Range/sensitivity is 0-200 ppm/4 ppm Cl.
Ship Code: (R2) Hazardous Material - Air Fees Applicable
Specifications |
|
---|---|
Test Factor: | Chlorine |
Test System: | Direct Reading Titrator |
Range/Sensitivity: | 0-200 ppm/4 ppm Cl |
# of Tests: | 50 at 200 ppm |
# of Reagents: | 3 |
† WARNING Proposition 65 Information: Cancer and Reproductive Harm - www.P65Warnings.ca.gov/chemicals
Ship Code: (R2) Hazardous Material - Air Fees Applicable
EO20231603
Request Quote
The Legionella Kit uses Lateral Flow Immunochromatographic Assay (LFICA) technology to detect the presence of cell surface scavengers of Legionella bacteria. It uses Legionella tests, labeled with red nanoparticles, which are found in any bacteria found in the sample and make them visible as a line on the device. The test works just like a pregnancy test: one line indicates a negative result and two lines indicate a positive result.
Specs | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Detected bacteria | Legionella pneumophila serogrupo 1 | ||||||||||
Detection Method | Lateral flow immunochromatographic assay. | ||||||||||
Lower Limit of Detection | As low as 100 UFC / L (0.1 UFC / ml) | ||||||||||
specificity |
Tested against a wide range of waterborne bacteria, including Acinetobacter calcoaceticus, Aeromonas hydrophila subsp. hydrophila, Bacillus subtilis, Burkholderia cepacia, Citrobacter freundii, Citrobacter koseri, Escherichia coli, Enterobacter cloacae, Klebsiella oxytoca, Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas putida,
|
||||||||||
volume test | 100 μL | ||||||||||
Suggested Sample Volume | 250 ml | ||||||||||
Sample Parameters | The sample should be filtered in less than 10 minutes. | ||||||||||
Biocides | The product has been tested with a range of common biocides and biodispersants used in the control of Legionella, at their normal maximum operating concentration. Active ingredients tested include: glutaraldehyde, dodecyldimethylammonium chloride, isolthazoles, dibromonitrilepropionamide, ionic and nonionic surfactants. The test gives a false positive if used with polymeric biguanide or THPS. It should not be used to test such systems. |
||||||||||
Operator Time | 5–10 minutes | ||||||||||
Operator Time | 25 minutes | ||||||||||
Duration | 18 months from the date of manufacture, when stored at room temperature (<30°C) in its original packaging. All test strips are tightly wrapped and stamped with an expiration date. |
EO20230303
$ 70.50 USD
Stretch membrane. Standard Membrane Kit for polarographic probes. Includes KCL electrolyte (1 mil). Specifications...
$ 1,400.00 USD
The multi-detector optical configuration assures long-term stability and minimizes stray light and color interference. The new ratiometric design allows for easy and accurate testing. The nephelometric mode measures 0-40 NTU/FNU, ratiometric mode 40-1000 NTRU/FNRU and 1000-2000 AU. Now pinpoint the range of interest with better, more reliable results. Ideally suited for low-level drinking water applications, mid-range industrial applications, and high-range environmental applications.
version meets US EPA design criteria as specified by EPA 180.1, Rev. 2.0 (1993) and Standard Methods 2130 B-2001.
version meets design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO 7027. Best for colored or extremely turbid samples.
Kits are supplied with 0, 1, and 10 NTU standards (Code 1974-T) or 0, 10, 100 FNU (Code 1974-I)
🟢 This product has no import restrictions.
Mode |
Ratiometric |
Nephelometric |
Attenuation |
---|---|---|---|
Unit of Measure 2020t: | NTRU, NTU, ASBC, EBC | NTU, ASBC, EBC | AU, NTU, ASBC, EBC |
Unit of Measure 2020I: | FNRU, NTU, ASBC, EBC | FNU, NTU, ASBC, EBC | FAU, NTU, ASBC, EBC |
Range: | 0-1,000 NTRU/FNRU 0-17,500 ASBC 0-250 EBC |
0-100 NTU/FNU 0-1,750 ASBC 0-25 EBC |
0-2,000 AU/FAU 0-35,000 ASBC, 0-500 EBC |
Resolution: | 0-10.99 NTRU/FNRU: 0.01 11.0-109.9 NTRU/FNRU: 0.1 110-1000 NTRU/FNRU: 1 |
0-10.99 NTU/FNU: 0.01 11.0-100.0 NTU/FNU: 0.1 |
0-2000 AU/FAU: 1 |
Accuracy: | 0-2.5 NTRU/FNRU: ±0.05 2.5-100 NTRU/FNRU: ±2% 100-1000 NTRU/FNRU: ±3% |
0-2.5 NTU/FNU: ±0.05 2.5-100 NTU/FNU: ±2% |
0-2000 AU/FAU: ±10 AU/FAU or 6%, whichever is greater |
Detection Limit: | 0.05 NTRU/FNRU | 0.05 NTU/FNU | 10 AU/FAU |
Range Selection: | Automatic | ||
Light Source: | 2020t: Tungsten lamp 2300° K ±50° K; | 2020i: IR LED 860 nm ±10 nm, spectral bandwidth with 50 nm | |
Detector: | 2020t: Photodiode, centered at 90° and 180°, maximum peak 400-600 nm; | 2020i: Photodiode, centered at 90° and 180° | |
Meter Specifications | |||
Signal Averaging: | Disabled, 2, 5, 10 | ||
Power: | USB computer cable, wall adapter or Lithium ion rechargeable battery, 3.7V, 2.5" x .75", 1.7 oz | ||
Data Logging: | 500 points | ||
Auto Shut-Off: | Disabled, 5, 10, 30 seconds | ||
Languages: | English, French, Spanish, Japanese, Italian, Portuguese, Chinese | ||
Response Time: | 2 seconds | ||
Size: | 7.5 x 3.5 x 2.5 inches | ||
Weight: | 13 ounces | ||
Display: | 6-line LCD with backlit display |
EO20232504
$ 348.00 USD
🔴 Due to the content of this product, delivery times may be increased due to the customs processing required.
LaMotte model AQ-2 freshwater aquaculture testing equipment
Ideal for freshwater analysis. It allows you to efficiently and accurately perform nine critical field tests. The unit comes complete with laboratory equipment, accessories, a sampling bottle, and reagents for 50 tests of each factor.
Octa-Slide comparative tests - Ammonia nitrogen, range: 0, 0.05, 0.1, 0.25, 0.5, 1.0, 1.5, 2.0 ppm. Nitrite nitrogen, range: 0.05, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 ppm. pH, range: 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5. Direct reading titrator: alkalinity, range/sensitivity: 0 to 200 ppm/4.0 ppm. Carbon dioxide, range/sensitivity: 0 to 50 ppm/1.0 ppm. Chloride, range/sensitivity: 0 to 200 ppm/4.0 ppm. Dissolved oxygen, range/sensitivity: 0 to 10 ppm/0.2 ppm. Total hardness as CaCO3, range/sensitivity: 0 to 200 ppm/4.0 ppm. Temperature - Shielded thermometer, range/sensitivity: -5°C to +45°C/0.5°C.
Test Type | Test Factor | Range | Sensitivity |
---|---|---|---|
Octa-Slide Comparator Tests | Ammonia Nitrogen | 0.0, 0.1, 0.25, 0.5, 1.0, 1.5, 2.0 ppm NH3-N | N/A |
Nitrite Nitrogen | 0.05, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 ppm NO2-N | N/A | |
pH | 5.0, 6.0, 6.5, 7.0, 7.5, 8.0, 9.0, 10.0 pH | N/A | |
Direct Reading Titrator Tests | Alkalinity (Total) | 0-200 ppm as CaCO3 | 4.0 ppm |
Carbon Dioxide | 0-50 ppm CO2 | 1.0 ppm | |
Chloride | 0-200 ppm Cl | 4.0 ppm | |
Dissolved Oxygen | 0-10 ppm O2 | 0.2 ppm | |
Hardness (Total) | 0-200 ppm as CaCO3 | 4.0 ppm | |
Temperature | Armored Thermometer | -5° to 45°C | 0.5°C |
Shipping | Ship Code: LQ (Hazardous Material - Air Fees Applicable) | Ship Weight: 16 lbs |